Metadata and ticketing system
After each site visit (maintenance or new installation) please fill out this metadata survey. If any errors or issues appear please contact Rebecca Hochreutener
While in the field you can use this word document (English, French) as a paper support.
Station tickets
scan for the metadata survey forms.
CDMSManual-V2
ATMOS 41 sensor suite
- ATMOS 41 manual (sensor suite)
- ATMOS 41 quick start guide (sensor suite)
- ATMOS 41 – Firmware update and re-zeroing of the wind speed
- ATMOS 41 – cleaning instructions
- Swapping ATMOS 41 daughter board
- Swapping ATMOS 41 funnel – pyranometer sensor
- Other ATMOS 41 documents
- ATMOS 41 firmware updates: ATMOS_41-R5-29-Updater
ZL6 data logger
- ZL6 user manual
- ZL6 Quickstart guide
- Firmware updater ZL6 (firmware images for manual update)
- Manual for updating ZL6 firmware manually
EM60G data logger
- EM60G manual (data logger)
- EM60G quick start guide (data logger)
- Meter USB Driver 8.0
- Firmware updater EM60G (firmware images for manual update)
- Manual for updating EM60G firmware manually
ZSC
- ZSC manual and quick Start Guide
- ZSC mobile app
- Manual to investigate sensor battery drainage using the ZSC Bluetooth sensor interface
ProCheck
- ProCheck firmware update: ProCheck-R1-73C updater
- ProCheck Manual
ECRN-100 Rain Gauge (High Resolution)
What are some good tips for installation?
Location
Make sure the location you choose will give you answers to the questions that you want answered. If you’re looking for general weather monitoring, make sure the location is far (at least 3X the height of the tallest obstruction) from any obstructions to the wind. Make sure the vegetation is representative, and make sure the topographical location is representative. Rooftops are pretty bad generally, as are deep valleys or hilltops. If you’re looking for reference ET, you’ll want to deploy in the field with at least a few meters of the crop on all sides of the installation. Also, make sure that nothing is going to shade the solar radiation sensor.
Height
A lot of groups mount the ATMOS 41 at 2 m height because this is the norm for reference evapotranspiration. Others go higher for meteorological observations. Some even deploy in the canopy for specialized research questions. You can deploy easily at whatever height you want as long as you have the right mounting apparatus
Mounting apparatus
The ATMOS 41 is designed to mount on a vertical rod (see the user manual and quickstart guide for exact dimensions). It is often deployed on a vertical pole anchored by either guy wires or a good-quality tripod. Some even mount on T-posts, preferably with some guy wires to add stability.
Level
This is important for ATMOS 41. You need to have it level to within 2 degrees in both the X and Y. There’s a bubble level underneath the rain funnel that you can see from below and use to get level. The ATMOS 41 also outputs x and y level as standard outputs, so you can make sure you’re within 2 degrees of zero. You’ll need to use the guy wires to pull the mounting apparatus level or add some shims to achieve the proper level.
Check the data flow before you leave the field
Take a laptop (or handheld device if you’re using the ZL6 data logger) and the right software to make sure all the connections are good and that your data acquisition system is recording and/or transmitting data properly. A good best practice is to set it all up in the lab or office first, troubleshoot any issues, and then go to the field.
Tidy up the wires
The single biggest failure mode for environmental sensors is the wiring. Zip-tying extra wire to the mounting mast can keep it from getting snagged by animals or whipped around in windstorms and unplugged from the data logger. Protecting the wiring in a cage or other container is great if you have the ability to do so. Any of these things make the installation look more professional, which is an added bonus
Always take a complete toolset
You never really know what you’re going to need when troubleshooting unique situations.
Weather station installation mistakes to avoid
Ever spent hours carefully installing your weather station in the field and then come back only to discover you made mistakes that compromised the installation? Or worse, find out months later that you can’t be confident in the quality of your data. Our scientists have over 100 years of combined experience installing sensors in the field, and we’ve learned a lot about what to do and what not to do during an installation.